Differential Scanning Calorimetry (DSC) Testing
DSC can determine a variety of thermodynamic and kinetic parameters, such as specific heat capacity, reaction heat, heat of transition, phase diagram, reaction rate, crystallization rate, polymer crystallinity, sample purity and so on. The method has the advantages of wide temperature range (-175 to 725 ℃), high resolution and small amount of samples. It is suitable for the analysis of inorganic, organic compounds and drugs. At the same time, DSC can quantitatively determine various thermodynamic parameters with high sensitivity and low working temperature, so it is widely used, especially in the fields of polymer, liquid crystal, food industry, medicine and biology. As a professional reliability third-party testing organization, T,C&A Lab can provide DSC testing service according to ISO, ASTM standards and industry requirements. Welcome to contact our experts for consultation.
Analysis and testing capabilities of DSC
- Melting and crystallization process
- Glass transition
- Oxidation stability/oxidation induction period
- Polycrystalline
- Compatibility
- Reaction heat
- Thermal stability
- Characteristic temperature
- Crystallinity
- Phase transition
- Specific heat
- Liquid crystal transition
- Curing
- Reaction kinetics
- Purity
- Material identification
DSC can provide test data for the following materials
- Polymer
- Plastic
- Composite materials
- Laminate
- Coating
- Drugs
- Organic materials
- Rubber
- Petroleum
- Chemicals
- Biological samples
DSC analysis process
- Early consultation
- Send sample for DSC analysis
- Engineer quote
- Pay testing fees and carry out experiments
- Complete the experiment and issue a test report
- Send test report, after-sales service
Standards we test to
- ASTM E 793, ASTM E 794, ASTM E1269, ASTM E 928, ASTM D 3895, ASTM E 537, ASTM E 698
- ISO 19935, ISO/DIS 11357, ISO 18373, ISO 28343, ISO 17321, ISO 22768, ISO 14322, ISO 15309
In addition, the experts in our Differential Scanning Calorimetry (DSC) Laboratory also provide a variety of custom services as your needs and requirements. Let's discuss the custom services with our experts for free.
Instruments and data


Reference
- Skotnicki, M.; et al. Bisoprolol and bisoprolol-valsartan compatibility studied by differential scanning calorimetry, nuclear magnetic resonance and X-ray powder diffractometry. Pharmaceutical research 32.2 (2015): 414-429.
T,C&A Lab's services include, but are not limited to
Note: this service is for Research Use Only and Not intended for clinical use.
Menu
-
Material Testing
-
Ingredient Analysis
- Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES)
- X-Ray Fluorescence (XRF) Testing
- X-Ray Photoelectron Spectroscopy (XPS) Testing
- Infrared Spectroscopy Testing
- Ultraviolet Spectrum (UV) Testing
- Mass Spectrometry Testing
- Micro-Raman Spectroscopy Testing
- Nuclear Magnetic Resonance Spectroscopy Testing
- Elemental Analysis
- Structural Characterization
- Morphology & Size Analysis
-
Corrosion Testing
- Corrosion Inhibitor Testing
- Crevice Corrosion Testing
- Electrochemical Corrosion Testing
- Galvanic Corrosion Testing
- High Pressure High Temperature (HPHT) Corrosion Testing
- Hydrogen Embrittlement Testing
- Intergranular Corrosion (IGC) Testing
- Pitting Corrosion Testing
- Salt Spray Testing
- Sour Service Corrosion Testing
- Stress Corrosion Cracking (SCC) Testing
- Sulfide Stress Cracking (SSC) Testing
- Thermal Analysis
- Mechanical Testing
- Non-Destructive Testing
- Performance Testing
- Pharmaceutical Testing
-
Metallurgical Analysis
- Chemical Analysis
- Case Depth Testing and Analysis
- Grain Size Analysis
- Particle Size Distribution Analysis and Testing
- Coating Thickness Testing
- Inclusion Rating
- Ferrite Testing
- Porosity Testing
- Grain Flow Testing and Analysis
- Weld Testing
- X-Ray Diffraction (XRD) Analysis
- Scanning Electron Microscopy (SEM) Laboratory
- Harmful Substances Testing
- Reverse Engineering & Deformulation
- Karl Fischer (KF) Moisture Testing
- Industrial Problem Diagnosis
-
Ingredient Analysis